Got a new motor, it made humming noise since day on,if i help it spin it works so I changed the capacitor and still the same, humming and if I help it to spin it goes fine, any suggestions? Your 1 hp Hayward Superpump can pump 75 gallons per minute, which is too much flow for most AG pool filters. Please note: The majority of our literature and brochures are in English only. See page 40/41 in this Hayward Troubleshooting guide. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. I have a hayward sp2610x15 1.5hp pump that I got in May 2017. Have a Hayward pump for above ground pool.when I start the pump it works properly and then itll stop pumping water. The salt level is 2300 ppm or less and no chlorine is generating. Hi Ray, the GFI breaker you replaced, is that the pump breaker? Third, is that breakers sometimes dont last forever, and can be go bad, usually after 20-30 yrs tho. I wonder if I should spend the $200 for replacement control board, or if there is a better fix. The pump has power, turns on, and seals are tight, however it will not cycle the water. Could vibration over time wear the pump housing? My pump was tripping the breaker after about three minutes (consistently when I reset the breaker and turned on the pump, same thing). Any advice?? If the new pump produces greater flow rate than the old pump, it produces high pressure, and poor filtration, and can damage the cartridge. Now it wont flip back on but it is still raining hard. Another check to do is to place the multiport valve on recirculate, which bypasses the filter, and will let you know for sure that the problem is in the filter sand. Most pump breakers are not GFI, it might not trip if it is a regular non-GFI. Hi Robin, an F5 code? Test to see if 120V (+/- 10%) is coming into the motor, on the two wire terminals. Only get big time cavitation and the basket empties about half. The filter caterige is brand new too. Maybe a complete reboot at the circuit breaker could be the answer, or a reset on the pump control panel. When I flip a switch to manually turn on to high speed, it does not work it is still working at low speed. If it blows again then I guess youll have to replace the pump body, which is usually about $100-200 cheaper than the cost of the whole pump. My Hayward Pump will pull the water through the basket really strong for about 45 seconds then the flow will stop for 20 seconds and the flow will then resume again. Try to spin the impeller with your fingers, or turn the motor shaft to check that it spins freely, or if not, put a wrench on the shaft and break the rust free. I changed the GFI Breaker in the main panel, problem still the same. I have 2 extension cords running to plug it in. What could be wring? Hi, my name is Javier Disconnected the chlorination device, and direct connected it eliminating that. If they wont or cant fix it, call a electric motor repair shop to visit, or pull the pump and take it to them for service, or attempt the (easy) repair yourself. I hooked everything up, and Im getting a lot of air returning into the pool. When I turn on my pump it runs normal for 5 seconds thank it winds down then reverts back to normal speed. It could also be just too much moisture on the motor terminals. When iturned it back on, it ran for a few seconds, sounded funny, then shut off. Interesting enough, if I place it in super chlorinate mode, it will produce chorine. Copyright 2022 In The Swim. Too bad Hayward doesnt make this more clear on their installation instructions and labeling. Thank you. If it still trips the breaker, it may have shorted out the motor windings, and is not repairable. Hi Don, if you have four suction lines coming into the pump, that would be skimmer, skimmer, main drain and spa drain? After running the pool for a few hours we realized the pump was leaking and EXTREMELY HOT. Any suggestions? Likewise, check if the motor is wired correctly for the available field supply voltage. If the cell is still producing chlorine, it should be fine. Without seeing the union and setup, it is hard to say what is causing it but check for warping of the nut. Just started getting a No Flow error. If the control exceeds the maximum number of ignition retries or recycles the heater will shut down and go into lockout. It can also just be a really dirty filter, or a clogged pump impeller. Or, it could be that the motor is cavitating, and restricting the return side somewhat may balance the flow, if you have a valve or bypass arrangement, or can plug one of the returns, for testing. Could be a change in vibration, press down on the pump, to see if the tone changes. (The factory default is 2800 ppm). Most likely, and unfortunately yes. We purchased a Hayward Pump SP3220EE and I need to know how They are higher voltage or whateverbut could that be the problem? If I wait for a few minutes after that, the pump starts up again at full speed. Setting it up this year and the pool filter lid keeps leaking. 3 possible solutions. Occasionally, while running, it trips the breaker. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. Pump lids are often easier to remove when the Filter Air Bleeder is opened, to relieve vacuum pressure. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. On page 30 of the Aquarite troubleshooting guide, it goes into depth about troubleshooting that rectifier. Also, DE filters need to be opened up and hosed down completely clean every 6-9 months, and then started up again with a full charge of DE powder. Are all connections tight? Don't stress! The pump itself works great. Could also be a clog in the pipe. It just started leaking at the top plumbing connection. Hi Michael, that could be a bad or weak capacitor, or a loose wire to the pump motor or to the outlet, or a bad power cord. Same thing with the pump lid, there is an o-ring that on some pumps can fall off the lid when the lid is removed, or become mis-positioned. Hi Leah, when the pump is barely pumping, the problem is either in front of the pump or after the pump. It likely also got hot and the threads shrunk, now drawing in too much air for the pump to catch prime. *If your water temperature reads 215 degrees F, the cell temperature sensor is shorted and your cell needs replacing. I have a Hayward Ultra Pro LX pump. When the problem is after the pump impeller, like a clogged filter, closed return valve or clogged return line, the pressure will be higher than normal. Happens all the time to pool pumps, and the way to un-stick it is to do some disassembly in the rear of the motor, to get a wrench on the slotted rear of the motor shaft, and work the shaft back and forth for a minute, to break the rust seal, and get the shaft to turn again. Sometimes it is just a stick or debris stuck between the valve diverter (aka rotor or footpad) and the spider gasket, and a little wiggle or jiggle or repositioning of the handle can seal up the waste port, for a time If it reoccurs, this means that the spider gasket is twisted, worn or damaged. there is an air leak, on the pump lid, or around the pipe that comes into the pump, or the pump drain plug. When the pool guy switched it, it worked very well for about a month with no issues at all. Another reason for a smoking pump is an incorrectly installed shaft seal, or blown capacitor. New Assy is $500. "name": "In The Swim",
We opened our pool a week ago and havent had a problem until today (May 23. If so, put a damper under the pump, a piece of heavy rubber or a shim to stabilize the pump. I would recommend getting a plug-in timeclock so you dont need to plug/unplug it all the time. It has been operating properly in its current setup for atleast 2 years (came with house). Pump lid not on tight enough After communication is established, if it is lost for 30 s, the error will be displayed. how to watch past broadcasts on twitch. You can only compare 4 products at a time. My 4 year old pump is working well so I am not looking to switch it, but I am curious if I should consider raising its location to above pool water level. If dead, you can replace just the motor and shaft seal, re-using the pump and impeller. Then we hear a click and the whole display goes blank. By morning all the dead algae filters back into the pool and it take about 4 days to clear. There may also be air leaks on your pump, particularly the pipe or valve that is threaded into the pump, must be sealed with thread sealant tightly. It need not be a fancy $100 meter, it can be a $10 meter from Radio Shack. Hi Keri, I understand, with Hayward Valves, incl the most common top mounted sand filter valve SP0714T, have the Spider Gasket molded to the underside of the rotor. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Two going bad? If there is an external 2-speed timeclock, check the wiring, esp. If thats not it check the rear of the motor for anything loose (capacitor, centrifugal switch (in the center, on the shaft) or the stationary switch, at 6 oclock, triangular shape. Check the capacitor, for bulging, cracking, or melting. Check in morning and basket is half full with water trickling in basket. Ive checked out your blog and you had very good info for audience. You can check the visual motor check (if you have an intermatic clock), to see if the motor gears are turning, which means the timeclock motor is good and the power from the breaker is good. There is not much that can be done to increase flow rates for a smaller pump, with exception to reducing plumbing restrictions with larger pipe size and less elbows, etc. . Finally, could be that the voltage is not quite right, one of the legs (power wires) not providing enough power. Ive tried everything. Also be sure the vent holes for the motor are not blocked. But not a dirty filter? Hard pumping can also cause a pump to overheat, but not usually. Especially a drip from the clamp band or the threaded fitting on the outlet port of the pump, or a dripping shaft seal, or leaking housing. Hi Shannon, right now it is a defective capacitor, not sure about the rest of the motor, but is probably OK. Thanks for the comment, impellers dont normally wear out, they either work or they are flat busted and dont work. If you suspect your breaker has broken, call a certified electrician to further diagnose the problem. We had a bad storm and a lot of rain come through. You might also check the the motor is not bound up, reaching in behind the basket to be sure you can spin the impeller with your fingertips. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The arrow should point in the same direction as the water flow. Could be the pump lid, drain plug, or the pipe that threads into the pump. Hello, I have a H200 natural gas heater . To view these documents, you will need to download the free Acrobat Reader, which All cords are fine. Just bought a hayward super II pump. It worked fine just prior to a filter cleaning. Also possible that the rubber is damaged, inspect closely for signs of wear while cleaning it. When you installed the new lateral assy, did the standpipe come all the way up to the top of the tank, and insert neatly into the bottom of the multiport valve? Pumps normal pressure and pulls enough volume to keep bakery full. The problem lies where the power dies [note to readers: motor cycling is not the same as pump cycling, where the water flow starts and stops, here I am talking about the motor itself starting/stopping], I have a Hayward sp2607x10 pump. We have a sand filter and no pressure gage. last year, I replaced the Sand & O ring on the filter, and I resealed the O ring on both the filter & Pump with O ring lube. Hello. If your cell looks like 4B, follow the instructions below for cleaning your cell. It doesnt mean it is ready to go at 230. "@type": "ImageObject",
A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. Also the pool breakers are loose now. Hello, Hi Doug, my first guess would be that the motor was set to accept 230V but was given 115V, or vice versa. Outlet works fine. What do you suggest? Im very new to pools & pool maintenance in general. I have tried everything, please help because I am running the filter all the time. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. Remove the filter cartridge to see if it continues. Its concerning to suddenly hear strange sounds coming from your Hayward pool pump. Also, make sure you plug in the cell all the way. Any ideas on what may be going on? Upon resetting an electrical short sound came from the pump motor tripping the breaker a second time. Hi Lou, I call that surging, and when a pump does that, and the water level (in the pool) is good, and a stuck skimmer weir is not causing the problem, I would check for an air leak in front of the pump a small void before the impeller that is pulling air in. "url": "https://blog.intheswim.com/"
If you have an electric motor repair shop in town, they may have it in stock, or order it online. "publisher": {
Maybe not a pump issue, but supply issue. 4. Or to a light switch and then to a breaker, that would be more of a standard installation. The hot side goes into the timer's N0-3 and common into com-1. Now that i have my new liner in and pool is filled i started adding chemicals to the pool and i went to turn the switch on and there is nothing happening with the motor. 93 should not be melting the plastic shrouds? Checked to make sure nothing was blocking it. The display shows nothing as if it is not getting power. A hum sound is usually associated with a bad capacitor (motor rear, 9 oclock), however the capacitor is a battery that is only used on start-up, and is released within a second of start-up, but still could be related. I heard like a crank sound, as if somethings stuck between a propeller if there is. Slide your main switch to the AUTO position. There must be a leak. The pump is 18 yrs. Pump making loud grinding noise, any solutions. By looking at the return valve, you should be able to see if it is squarely closing off the pool return pipes. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell. Hi Lo in checking the owners manual https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, it suggests bypassing the timeclock and wiring direct to the breaker. Some very old pumps have impellers that need shimming from time to time, or resetting the distance from the volute, but thats with keyed shaft motors, on older bronze pumps (not plastic). Getting ready to start up my pool , flipped the breaker and nothing. I will re-check all the wiring. (returns are the lines going back to the pool, returning) Some pools can operate successfully with fewer than the original pipes, I have worked on many pools with abandoned main drains or skimmers that stopped working. Hi Douglas, it could be the capacitor, if youre lucky. I turn it off at the breaker & then turn it back on again, it displays rESET. Fault with the pump wiring. So we cannot manually rotate the shaft a full revolution. "identifier": ""
When the centrifugal switch is pushed flat by the spinning shaft (or with your finger [power off! No matter where we move dial we have water coming out the back wash pipe. Breville Tamper Coffee Kit 54mm, Power is getting to the pump but the pump will not run?. FYI I moved the voltage selector to 115. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. 58 amps! Hi! Remove the two wires connected to the capacitor, with a small flathead, or needle nose pliers. Is there something I forgot to do? Flipped the breakers back on this morning after problem fixed. Its likely good advice you are getting. Shaft seals may blow out if a valve after the pump is turned or briefly closed while the pump is running. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 We would like to show you a description here but the site wont allow us. I have mud in my filter so I guess I have a underground broken pipe. Buckle Black Bootcut Jeans, Wouldnt, the other three still be sufficient to filter? The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. Hi David, impellers that have signs of wear are usually operating without a problem. we bought a hayward super pump for inground pool ever since installing pump we are able to vacuum pool for about 5 minutes then loose suction with filter gauge rising to near 30. if we turn off pump and restart the pump returns to normal with filter gauge registering at 18, we have replaced vacuum hose, checked laterals in filter, checked piping for leaks. That is usually what causes the rattle. The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. Are you using enough DE powder? There is also a leak somewhere in the system because there is water on the pad. This one is 5 years old. Similar pumps, with the same flow rate characteristics, are not less expensive. They function as the starting battery for the motor, to help it get up to speed quickly. Hi, the yellow wire could have been hit by the whirling centrifugal switch in the center rear of the motor, or could have burned thru from touching something very hot. Currently it is at pool level. I also replaced the seals. Look closely at the suction-side (incoming pipes/valves, up to the strainer pot), and shut off pump, watching closely for water spray, or sometimes just a fast dribble. You are also using the diffuser? Hi Carl, check for an air leak in front of the pump on the suction manifold, or around the pump lid, or on around the threads of the fitting that screws into the pump. 8. check power at the motor, with a multimeter set on 240V+ place test probes on the brass screws or terminals where the two power wires connect. Or do I have a friction issue in the impeller? I then plugged the pump into the outlet and it tripped again. 20amp fuse is not blown. Any new postings here are unlikely to be seen or responded to by other members. We have our pump timers to shut off at noonmany times, but all the time, they run past the specified shut off time. Air can also be drawn into the pump from leaky suction side valves (skimmer or main drain). Bob. If the shaft does spin fine, and is not locked up, you can try a new capacitor, or check your current cap, with an ohmmeter. If you have a power meter you can turn clock on and see if power is getting to the motor 110-120V. But after that, you should be able to override any programs with the buttons. started having the problem
Melissa Mcgurren Engaged, Key Worker Housing Hertfordshire, Porsche Boxster Ev Conversion Kit, Riddles About Wood Piles, John Maura Smith Ranch Homes, Articles H